Fluke FLUKE-718EX 30 Intrinsically Safe Pressure Calibrator
Features and Specifications
- Range: -830 mbar to 2 bar (internal sensor)
- Over pressure: 3x FS
- Resolution: 0.0001 bar
- Accuracy: 0.05% FS
- Functions: Zero, Min, Max, Hold, Damp
- Power: One 9-volt alkaline battery
- Battery life: 4 to 20 hours, depending on functions used
FLUKE-718EX 30 Overview
The Fluke 718EX-30G Intrinsically Safe Pressure Calibrator is designed to calibrate P/I (pressure to current) transmitters, a task it accomplishes with precision. The device is equipped to measure pressure through a 1/8-inch NPT pressure fitting and an internal pressure sensor. Alternatively, it can also utilize Fluke 750PEx Series Pressure Modules for this purpose.
In addition to pressure, the Calibrator can measure current up to 24 mA, demonstrating its multifunctional nature. One of its highly useful features is its ability to simultaneously display pressure and current measurements, providing a comprehensive view of the parameters being monitored. Furthermore, it can perform switch testing, adding to its repertoire of functions.
The Calibrator is not only functional but also precise. It provides 5-digit pressure readings in a variety of units including psi, inH2O at 4 C, inH2O at 20 C, kPa, cmH2O at 4 C, cmH2O at 20 C, bar, mbar, kg/cm2, inHg, and mmHg. Its full-scale pressure sensor input is 206.85 kPa or 2.0685 bar, with an overload indication appearing at 33 psi. The device offers a resolution of 0.01 psi (0.01 kPa) and maintains an accuracy of 0.05% FS, ensuring reliable and accurate readings. This combination of versatility, functionality, and precision makes the Fluke 718EX-30G Intrinsically Safe Pressure Calibrator an invaluable tool in its field.
718EX Series
The new Fluke 718EX series of Intrinsically Safe Pressure Calibrator is a powerful new intrinsically safe, self contained pressure calibration solution that offers:
- ATEX II 1G Ex ia IIC T4 compliance
- I.S. Class I, Division 1 compliance
- Built-in pressure/vacuum hand pump, with vernier and bleed valve
- Pressure measurement to 0.05 % of full span, using an internal pressure sensor
- Pressure measurement to 3,000 psi/200 bar using any of the 8 intrinsically safe Fluke 700PEx Pressure Modules
- Wide range of selectable measurement units for pressure
- Current measurement with 0.02% accuracy and 0.001 mA resolution
- Pressure switch test function
- Min/Max hold functions
- Compact size and weight
- Simple, push-button user interface
- Rugged and reliable, for field use
- Pressure switch test function
Models Available in the Series
- Fluke-718EX-30G: -12 psi to 30 psi (-82.7 kPa to 207 kPa)
- Fluke-718EX-100G: -12 psi to 100 psi (-82.7 kPa to 690 kPa)
- Fluke-718EX-300G: -12 psi to 300 psi (-82.7 kPa to 2068 kPa)
What's in the Box
- Fluke-718EX-30G Intrinsically Safe Pressure Calibrator
- Protective holster
- TL75 test leads
- AC72 test clips
- CD users manuals in 14 languages
- Fluke 718Ex CCD control drawing