$EACH
- Description
- Specifications
- Documents
- Bandwidth: DC-25MHz
- Attenuation: X200, X20
- Accuracy: +/-2%
- Input voltage range
Less than or equal to +/-140V for x20
Less than or equal to +/-1400V for x200 - Permitted max input voltage:
Max differential voltage: 1400V(DC+AC PEAK)
Max voltage between each input terminal and ground: 1KV RMS - Input Impedance:
Each side: 4 Megaohms /2.5pF
Between sides:8 Megaohms /1.3pF - Output voltage: Less than or equal to +/-7V
- Output impedance: 50 Ohms
- Rise time:
14ns for x200
14ns for x20 - Rejection rate on common mode:
50Hz:>-80dB; 20KHz:>-66dB - Power Supply: 6V DC power supply.
- Consumption:0.3A max
The PT-8002 differential probe provides a safety means for measuring differential voltage to all models of oscilloscopes. It can convert the high differential voltage (less than or equal to +/- 1400V) into a low voltage(less than or equal to +/- 7V) and display on the oscilloscope. Its bandwidth is up to 25MHz, which is ideal for big power testing, development and maintain.
The PT-8002 is designed to operate with the 1 megaohm impedance oscilloscopes. When combined with the 50Ω ohms, the attenuation will be 2 times.
Brand: Probe Master
Bandwidth: 25 MHz
Attenuation: 200X, 20X
Input Capacitance: 1.3 pF
Max Input Voltage: 1400 V
Input Impedance: 8 MΩ
Series: PT-8000 Series
Operating Temperature Range: 0 to 50°C
Risetime: 14 ns
Safety Rating: CAT2 | CAT3
Type: Differential Probe
$EACH