- 16kVA / 16,000VA / 14,400W on-line double-conversion UPS, 0.9 power factor
- 200/208/220/230/240V 50/60Hz output
- Hot-swap power & battery modules, N+1 fault tolerance at loads up to 8kVA
- USB, RS232, EPO ports, slot for network management card options
- Front panel LEDs with detailed LCD monitoring and control screen
- Expandable runtime with optional external battery packs
- Hardwire input (3 wire), L6-20R and L6-30R outlets
Tripp Lite SU16KRTG 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.
■ Tripp Lite SU16KRT8 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configuration
■ Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under
■ Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level
■ Hardwire input; 8 L6-20R and 2 L6-30R outlets
■ Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal
■ Supports 50/60Hz operation for worldwide frequency compatibility
■ Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD (NOTE: Applications utilizing any supported network management card option, require the installation of two of the same model network card – install one card per included UPS power module)
■ Expandable runtime with optional external battery packs
■ Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
■ Battery independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries
■ Intelligent battery management system with temperature-compensated charging extends battery life
■ HID-compliant USB interface
■ USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
■ Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required)
■ Optional 2-9USTAND supports upright tower placement (2 required)
■ Supports Emergency Power Off (EPO) via built-in interface
■ Front panel LEDs and LCD readout with scroll controls
■ LED / LCD display panel rotates for viewing in rackmount or tower configurations
■ External battery packs are field replaceable and hot swappable
■ Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)