- Single phase 16A 200-240V Auto Transfer Switch / ATS PDU
- Enables redundant-power option for single-corded network devices
- Separate primary & secondary inputs connect to any two compatible power sources
- 1U horizontal rackmount; 2 C20 inputs; 8 C13 and 2 C19 outlets
- Two digit visual current meter; Upgrade options available
- Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
■ 200-240V 20A Automatic Transfer Switch (ATS) / Local Metered PDU (Agency de-rated to 16A continuous)
■ Provides a redundant power option for critical networking equipment with a single input power cord
■ 2 digit display reports output power consumption in amps
■ 1U horizontal rackmount form factor; 14.8 in. / 37.6 cm depth
■ 10 outlets (8 C13, 2 C19)
■ Set of Plug-lock output power cable retention sleeves prevent accidental disconnection of connected devices
■ Set of two C20 inlets support connection to separate PRIMARY and SECONDARY power sources
■ Two 12-ft. / 3.6m C19 to C20 power cables included
■ ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
■ ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
■ Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
■ On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
■ Super-fast switchover between primary and secondary power sources occurs in 2-5 milliseconds
■ Built-in card slot supports optional SNMPWEBCARD or WEBCARDLX for permanent upgrade to a switched & monitored PDU system
■ Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup
■ Front panel LEDs confirm power availability on both input lines
■ Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases