Continuously monitors the path-to-ground integrity of one operator and one ESD worksurface. Mounting tabs make it suitable to install in workbench or equipment settings. Connect the 19332 Light Tower accessory for increased alarm visibility.
Designed with Wave Distortion Technology which provides stable continuous monitoring of the path-to-ground and presence of 1 megohm resistance of an operator’s wrist strap. Audio and visual alarms activate (in less than 50 milliseconds) when the operator unintentionally disconnects from the monitor or the wrist strap connection points are intermittent. The Multi-Mount Continuous Monitor also monitors for a worksurface path-to-ground of less than 10 megohms. All Multi-Mount Continuous Monitors are calibrated to NIST standards.
Features:
- NEW Park Delay Timer and ParkSnap™
Indicates the 8 second delay to disconnect and park the operator wrist cord without creating a false alarm - Wave Distortion Technology
Provides stable continuous monitoring (versus pulsed or intermittent) of the wrist strap’s path-to-ground* and the presence of its 1 megohm safety resistor - Mat Monitor Switch
Disables the worksurface monitor circuit when used in areas where there is no ESD worksurface - Audible Alarm Adjustment
Sets the audible alarm volume from loud to louder - Enclosure with Mounting Tabs
Installs in workbench and equipment environments - Single-Wire Impedance Design
Meets ANSI/ESD S20.20 in accordance with ESD TR1.0-01-0 - 1.2 Volt Operator Test Voltage
Reduces the risk of electrical overstress (EOS) for the handling of sensitive components - <50 Millisecond Alarm Response Time
Identifies failures and intermittencies - NIST Calibrated
Calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology. - 100-240VAC Safety Certified Power Adapter with North American Plug
Works with standard electrical systems in North America, Japan, and Asia - Made in the United States of America