Agilent Digital Multimeter, TRMS, 34401A, 12 Functions
- Techni-Tool Part #: 431TE401
- Mfg Part #: 34401A
- Sold per: EACH
- Available in stock: 0
- Estimated weight:
14.15 lb
Regular Price: $1,072.00
Your price: $1,072.00
Shipping:
Measure DC and AC voltage and current, resistance, frequency, and period with laboratory accuracy and incredible system speed. Delivers results and convenient features that minimize test and troubleshooting times. One-Year Warranty.(USA)
Specifications: DC voltage Measurement method: Continuously integrating multi-slope III A-D converter A-D linearity: 0.0002% of reading + 0.0001% of range Input resistance: 10 MΩ or 0.1 V, 1 V, 10 V ranges: Selectable > 10,000 MΩ 100 V, 1000 V ranges: 10 MΩ ± 1% Input bias current: < 30 pA at 25°C Input protection: 1000 V all ranges dcV:dcV ratio accuracy: Vinput Accuracy + Vreference Accuracy
True rms AC voltage Measurement method: ac coupled true rms - measures the ac component of the input with up to 400 Vdc of bias on any range Crest factor: Maximum of 5:1 at full scale Additional crest factor errors (non-sinewave): Crest factor 1-2: 0.05 % of reading Crest factor 2-3: 0.15 % of reading Crest factor 3-4: 0.30 % of reading Crest factor 4-5: 0.40 % of reading Input impedance: 1 M. ± 2% in parallel with 100 pF Input protection: 750 Vrms all ranges Resistance Measurement method: Selectable 4-wire or 2-wire Ohms. Current source referenced to LO input. Maximum lead resistance (4-wire): 10% of range per lead for 100 Ω and 1 kΩ ranges. 1 kΩ per lead on all other ranges. Input protection: 1000 V all ranges DC current Shunt resistance: 5 Ω for 10 mA,100 mA; 0.1 Ω for 1 A, 3 A Input protection: Externally accessible 3 A 250 V fuse Internal 7 A 250 V fuse True rms AC currentN Measurement method: Direct coupled to the fuse and shunt. ac coupled true rms measurement (measures the ac component only). Shunt resistance: 0.1 Ω for 1 A and 3 A ranges Input protection: ExternalIy accessible 3 A 250 V fuse Internal 7 A 250 V fuse Frequency and period Measurement method: Reciprocal counting technique Voltage ranges: Same as ac voltage function Gate time: 1 s, 100 ms, or 10 ms Continuity/diode Response time: 300 samples/s with audible tone Continuity threshold: Selectable from 1 Ω to 1000 Ω Measurement noise rejection 60 (50) Hz1 dc CMRR: 140 dB ac CMRR: 70 dB Integration time and normal mode rejection2 100 plc/1.67 s (2 s): 60 dB3 10 plc/167 ms (200 ms): 60 dB3 1 plc/16.7 ms (20 ms): 60 dB < 1 plc/3 ms or 800 µs: 0 dB Operating Characteristics4 System speeds6 Configuration rates: 26/s to 50/s Autorange rate (dc Volts): > 30/s ASCII readings to RS-232: 55/s ASCII readings to GPIB: 1000/s Maximum internal trig. rate: 1000/s Max.ext.trig.rate to memory: 1000/s Triggering and memory Reading HOLD sensitivity: 10%, 1%, 0.1%,or 0.01% of range Samples/trigger: 1 to 50,000 Trigger delay: 0 to 3600 s: 10 µs step size External trigger delay: < 1 ms External trigger jitter: < 500 µs Memory: 512 readings Math functions NULL, min/max/average, dBm, dB, limit test (with TTL output) Standard programming languages: SCPI (IEEE-488.2), Agilent 3478A, Fluke 8840A/42A Accessories included: Test lead kit with probe, alligator, and grabber attachments Operating manual, service manual, test report, and power cord General specifications Power supply: 100 V/120 V/220 V/240 V ±10% Power line frequency: 45 Hz to 66 Hz and 360 Hz to 440 Hz Automatically sensed at power-on Power consumption: 25 VA peak (10 W average) Operating environment: Temperature: RTD, Thermistor Full accuracy for 0°C to 55°C Full accuracy to 80% R.H. at 40°C Storage environment: - 40° C to 70°C Weight: 3.6 kg (8.0 Ibs) Safety: Designed to CSA, UL-1244, IEC-348 RFI and ESD: MIL-461C, FTZ 1046, FCC Vibration and shock: MIL-T-28800E, Type III, Class 5 (sine only) Warranty: 1 year Notes: 1. For 1 kΩ unbalance in LO lead. 2. For power line frequency ± 0.1%. 3. For power line frequency ± 1% use 40 dB or ± 3% use 30 dB. 4. Reading speeds for 60 Hz and (50 Hz) operation. 5. Maximum useful limit with default settling delays defeated. 6. Speeds are for 4 1/2 digits, delay 0, auto-zero and display OFF.
|
|
|
|