Fluke i400s AC Current Clamp, Measure to 400 Amp AC
- Techni-Tool Part #: 374TE404
- Mfg Part #: I400S
- Sold per: EACH
- Available in stock: 0
- Estimated weight:
.87 lb
noinfofound
Regular Price: $245.95
Your price: $245.95
Shipping:
- High safety AC current clamp for DMM's
Fluke Current clamps are the ideal tools to extend the functionality of Fluke tools. The i400 is a single range 400 A ac current clamp with current output via safety shrouded banana plugs. The clamp is compatible with most Fluke multimeters or any other current measurement device that accepts 4mm-shrouded banana plugs and has an AC milliamp range. The division ratio is 1000:1.
High safety AC current clamp with BNC output
Companion to your scope or power quality meter to measure up to 400 A AC. Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating. Specially designed to offer maximum utility in a compact shape. Take accurate current readings without breaking the circuit. Soft non-slippery overmold handle. Optional PM9081/001 BNC/Banana adapter for DMM's Two ranges: 40 A & 400 A, 10 & 1 mV/Amp output. Max. conductor diameter 32 mm.
Specifications
Nominal current range: 40 A Range: 0.5A to 40 A 400A Range: 5 A to 400 A Basic accuracy: 40 A Range 2% + 0.015 A (45-400 Hz) 400 A Range 2% + 0.04 A (45-400 Hz) Phase Shift: 40 A Range: 0.5 to 1 A: Unspecified 1 A to 5 A: 4° 5 A to 10 A: 3° 10 A to 20 A: 3° 20 A to 40 A: 2° 40 A to 400 A: NA 400 A Range 5 A to 10 A: Unspecified 10 A to 20 A: 2° 20 A to 40 A: 2° 40 A to 400 A: 1.5° Typical Bandwidth: 40 A Range: 5 Hz - 10 kHz 400 A Range: 5 Hz - 10 kHz Output level(s): 40 A Range: 10 mV/A 400 A Range: 1 mV/A Crest Factor: 40 A Range: < 3 400 A Range < 3 to 300 A < 2.5 to 400 A
Safety Specifications
Safety: CAT IV 600 V, CAT III, 1000 V Maximum Non-Destructive Current: 1000 V AC
Mechanical & General Specifications
Warranty: 1 year Maximum conductor size: 32 mm (1.25") Output cable length: 2.5 m (8.2 ft) BNC Adapter: Yes Dimensions: 150 x 70 x 30 mm Weight: 114 g
- Specifications:
Nominal current range: 40 A Range: 0.5A to 40 A 400A Range: 5 A to 400 A Basic accuracy: 40 A Range 2% + 0.015 A (45-400 Hz) 400 A Range 2% + 0.04 A (45-400 Hz) Phase Shift: 40 A Range: 0.5 to 1 A: Unspecified 1 A to 5 A: 4° 5 A to 10 A: 3° 10 A to 20 A: 3° 20 A to 40 A: 2° 40 A to 400 A: NA 400 A Range 5 A to 10 A: Unspecified 10 A to 20 A: 2° 20 A to 40 A: 2° 40 A to 400 A: 1.5° Typical Bandwidth: 40 A Range: 5 Hz - 10 kHz 400 A Range: 5 Hz - 10 kHz Output level(s): 40 A Range: 10 mV/A 400 A Range: 1 mV/A Crest Factor: 40 A Range: ≤ 3 400 A Range≤ 3 to 300 A ≤ 2.5 to 400 A
Safety Specifications
Safety: CAT IV 600 V, CAT III, 1000 V Maximum Non-Destructive Current: 1000 V AC
Mechanical & General Specifications
Warranty: 1 year Maximum conductor size: 32 mm (1.25") Output cable length: 2.5 m (8.2 ft) BNC Adapter: Yes Dimensions: 150 x 70 x 30 mm Weight: 114 g
- noinfofound
|
|
|
|