Fluke 177 Digital Multimeter, 1000V, Backlight, Min/Max/Avg
- Techni-Tool Part #: 374TE177
- Mfg Part #: FLUKE-177
- Sold per: EACH
- Available in stock: 0
- Estimated weight:
2 lb
Regular Price: $269.95
Your price: $269.95
Shipping:
- Setting the new multimeter standard
Features
True RMS voltage and current measurements 0.09% basic accuracy 6000 count resolution Digital display with analog bargraph and backlight Manual and automatic ranging Display Hold and Auto Hold Frequency and capacitance measurements Resistance, continuity and diode measurements Min-max-average recording Smoothing mode allows filtering of rapidly changing inputs Easy battery exchange without opening the case Closed case calibration through front panel Ergonomic case with integrated protective holster EN61010-1 CAT III 1000V / CAT IV 600V Measures twice as fast as other multimeters
Specifications
Voltage DC Accuracy*: ± (0.09%+2) Max. Resolution: 0.1 mV Maximum: 1000 V
Voltage AC Accuracy*: ± (1.0%+3) Max. Resolution: 0.1 mV Maximum: 1000 V
Current DC Accuracy*: ± (1.0%+3) Max. Resolution: 0.01 mA Maximum: 10 A
Current AC Accuracy*: ±: (1.5%+3) Max. Resolution: 0.01 mA Maximum: 10 A
Resistance Accuracy*: ± (0.9%+1) Max. Resolution: 0.1 Ω Maximum: 50 MΩ
Capacitance Accuracy*: ± (1.2%+2) Max. Resolution: 1 nF Maximum: 10,000 µF
Frequency Accuracy*: ± (0.1%+1) Max. Resolution: 0.01 Hz Maximum: 100 kHz
*Note: Accuracies are best accuracies for each function
Environmental Specifications
Operating Temperature: -10°C to +50°C Storage Temperature: -30°C to +60°C Humidity (Without Condensation): 0% - 90% (0°C - 35°C) 0% - 70% (35°C -50°C)
Safety Specifications
Overvoltage category: EN 61010-1 to 1000 V CAT III. EN 61010-1 to 600 V CAT IV. Agency Approvals: UL, CSA, T V listed and VDE Pending
Mechanical & General Specifications
Size: 43 x 90 x 185 mm Weight: 420 g Warranty: Lifetime Battery Life Alkaline: ~200 hours typical, without backlight
Includes:Installed 9V battery, Test leads and user manual.(Made in USA with US and foreign parts
- Specifications:
Voltage DC Accuracy*: ± (0.09%+2) Max. Resolution: 0.1 mV Maximum: 1000 V
Voltage AC Accuracy*: ± (1.0%+3) Max. Resolution: 0.1 mV Maximum: 1000 V
Current DC Accuracy*: ± (1.0%+3) Max. Resolution: 0.01 mA Maximum: 10 A
Current AC Accuracy*: ±: (1.5%+3) Max. Resolution: 0.01 mA Maximum: 10 A
Resistance Accuracy*: ± (0.9%+1) Max. Resolution: 0.1 Ω Maximum: 50 MΩ
Capacitance Accuracy*: ± (1.2%+2) Max. Resolution: 1 nF Maximum: 10,000 µF
Frequency Accuracy*: ± (0.1%+1) Max. Resolution: 0.01 Hz Maximum: 100 kHz
*Note: Accuracies are best accuracies for each function
Environmental Specifications
Operating Temperature: -10°C to +50°C Storage Temperature: -30°C to +60°C Humidity (Without Condensation): 0% - 90% (0°C - 35°C) 0% - 70% (35°C -50°C)
Safety Specifications
Overvoltage category: EN 61010-1 to 1000 V CAT III. EN 61010-1 to 600 V CAT IV. Agency Approvals: UL, CSA, T V listed and VDE Pending
Mechanical & General Specifications
Size: 43 x 90 x 185 mm Weight: 420 g Warranty: Lifetime Battery Life Alkaline:
|
|
|
|