Fluke
Fluke-125 Scopemeter, 40 MHz, Industrial, Probe Included

  • Techni-Tool Part #: 374TE1253
  • Mfg Part #: FLUKE-125/003
  • Sold per: EACH
  • Estimated weight: 6.4 lb
Enter Amount $
 

This item has been added to your favorites

You must be logged in to add an item to your favorites, click here to login.
New customer? Click here to register.

Please select a value for each option before adding to your Favorites.

Close

  • ScopeMeter 120 Series: Three-in-one simplicity

    The compact ScopeMeter 120 Series is the rugged solution for industrial troubleshooting and installation applications. It's a truly integrated test tool, with oscilloscope, multimeter and "paperless" recorder in one affordable, easy-to-use instrument. Find fast answers to problems in machinery, instrumentation, control and power systems.

    A dual input 40 MHz or 20 MHz digital oscilloscope
    Two 5,000 counts true-rms digital multimeters
    Cursor measurements
    A dual input TrendPlot recorder
    Connect-and-View trigger simplicity for hands-off operation
    Shielded test leads for oscilloscope, resistance, continuity and capacitance measurements
    Full bandwidth, VPS40 10:1 40 MHz probe included
    Up to seven hours battery operation
    600 V CAT III safety certified
    Optically isolated RS-232 interface
    Rugged, compact case
    Bus Health test for industrial bus systems
    Power measurements and harmonics measurement.

    For more info, please see the Technical Specifications tab.
  • Specifications: Oscilloscope mode Vertical deflection Bandwidth (risetime): with VPS40 probes: 40 MHz input A and B directly: 40 MHz with STL120 Shielded Test Leads: 12.5 MHz Instrument risetime (input directly): 8.75 ns Number of inputs: 2 Input coupling: AC, DC with ground level indicator Input sensitivity: 5 mV to 500 V/div (with the included VPS40 and STL120 shielded test leads measure up to 600 Vrms, CAT III) Input voltage: 600 V CAT III. Vertical resolution: 8 bit Accuracy: ± (2 % of reading + 0.05 x range/div) Input impedance: 1 M? ± 1 % // 225 pF with STL120 shielded test leads; 1 M? ± 1 % // 20 pF ± 3 pF with BB120; 5 M? ± 1 % // 15.5 pF with VPS40, 10:1 Voltage probe Horizontal Max. sample rate (both channels simultaneously): 2.5 GS/s for repetitive signals; 25 MS/s for single shot Number of digitizers: 2 Maximum record length: 512 Min-Max points per input Accuracy: ± (0.1 % of reading + 1 pixel) Glitch detect: 40 ns Display and acquisition Display modes: Input A, input A and B, envelope, smooth Acquisition modes: Normal (including glitch capture), single shot, roll Trigger and delay Source: Input A, input B, external via optional ITP120 Modes: Automatic Connect-and-View, Free Run, Edge, Single Shot, Video, Video Line Connect-and-View: Advanced automatic triggering that recognizes signal patterns and automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable pictures of complex and dynamic signals like motor drive and control signals Video triggering: NTSC, PAL, PAL+, SECAM. Includes line select Time delay: Up to 10 divisions pre-trigger view Measurements: Vdc, Vac, Vac+dc, Vpeak max, Vpeak min, Vpeak to peak, frequency (Hz), positive pulse width, negative pulse width, positive duty cycle, negative duty cycle, Amp ac, Amp dc, Amp ac+dc, Phase, Temperature °C, Temperature °F, dBV, dBm into 50 W and 600 W. (Amps, °C or °F with optional probes) Cursor measurements Sources: Input A, Input B Modes: Single or dual vertical cursor, dual horizontal cursor, risetime or falltime Measurements: Single vertical line: Average, min value, max value, time from start of recording in roll mode Dual vertical lines: V at markers, time between cursors, 1/T between cursors (in Hz) Dual horizontal lines: High, low or V - readout, risetime and falltime: transition time, 0 %-level, 100 %-level, with markers at 10% and 90% Accuracy: As oscilloscope Bus health tester: Bus health automatically analyzes the electrical signals on the network to give waveform data and measure individual parameters. Automatic comparison of the measurement results to the standards results in "good" or "false" indicators to be displayed per parameter. Bus types and reference standards used: AS-I (EN50295); CAN-bus (ISO-11898); Interbus S (EIA-485); ControlNet (61158 type 2); Modbus (EIA-232 and EIA-485); Foundation Fieldbus H1 (61158 type 1, 31.25 kb) and H2 (61158 type 1); Profibus DP (EIA-485) and PA (61158 type 1); Ethernet [10Base2 (coaxial) and 10BaseT (UTP)]; RS-232 (EIA-232); RS-485 (EIA-485); or user defined system Measured parameters: Baud rate, risetime, falltime, high level, low level, distortion, amplitude and jitter, with comparison to system's standard values Power measurements Measure types: Watt, VA, VAR, Power Factor (PF) Power configuration: Single phase or balanced 3-phase (delta-configuration) mains supply Voltage measurement: Channel A, using STL120, voltage probe or direct input Current measurement: Channel B, using i400s current clamp (included) or other compatible clamp Current clamp sensitivity: 0.1/1/10/100/1000 mV/A, 10 mV/mA and 400 mV/A Harmonics mode:Converts waveform information into a harmonics display (using FFT processing), which shows the relative amplitudes of the 1st up to the 33rd harmonic Default setting: Harmonic contents of the power waveform Harmonics frequency range: DC to 33rd harmonic (fundamental < 60 Hz); DC to 24th (fundamental < 400 Hz) Analyzed waveform:Voltage waveform (Ch.A), current waveform (Ch.B) or power (Ch.A x Ch.B), automatically generated Display: Bargraph showing 1st up to 33rd harmonic, amplitude displayed in % relative to fundamental Timebase setting: 5 ms/div. Measurements: Relative amplitude of individual harmonic; THD in %r or %f Dual input meter: The specified accuracy is valid over the temperature range 18°C to 28° C (64°F to 82°F). Add 10 % of specified accuracy for each °C below 18°C or above 28°C (64°F to 82°F) Max. meter bandwidth: 40 MHz Voltage measurements Measurement selection: Vdc, Vac rms, Vac+dc rms, Vpeak max, Vpeak min, Vpk-pk Ranges: 500 mV, 5 V, 50 V, 500 V, 1250 V Full scale reading: 5,000 counts Accuracy Vdc: ± (0.5 % + 5 counts) Vac rms: 1 Hz to 60 Hz: ± (1 % + 10 counts) 60 Hz to 1 kHz: ± (2.5 % + 15 counts) 20 kHz to 1 MHz ± (5 % + 20 counts) Vac+dc true-rms: DC to 60 Hz: ± (1 % + 10 counts) 60 Hz to 1 kHz: ± (2.5 % + 15 counts) 20 kHz to 1 MHz (5 % + 20 counts) Vpeak: Max peak or Min peak: 5 % of full scale Peak-to-peak: 10 % of full scale Ohms Ranges: 500 W, 5 kW, 50 kW, 500 kW, 5 MW, 30 MW, 50.00 W Max. resolution: 5,000 counts Accuracy: ± (0.6 % of reading + 5 counts) Capacitance Ranges: 50 nF to 500 µF Max. resolution: 5,000 counts Accuracy: ± (2 % of reading + 10 counts) Other meter functions Frequency: Up to 70 MHz Rotational speed (RPM): Revolutions per minute, based on 1, 2 or 4 or 8 pulses per 2 revolutions Continuity: Beeper on < 30 ? Diode test: Up to 2.8 V Amps: Amp dc, Amp ac, Amp ac+dc using an optional current clamp or shunt. Scaling factors: 0.1 mV/Amp to100 V/Amp Temperature (°C, °F): With optional accessories. Scale factors 1 mV/°C or 1 mV/°F Number of inputs: 2 Input impedance: 1 M? ± 1 % // 10 pF ± 2 Pf Advanced meter functions: Auto/manual ranging, TouchHold®, Relative measurements (zero reference), TrendPlot recording Recorder mode Trendplot recording Dual input electronic paperless chart recorder. Plots and displays the actual, minimum, maximum and average of any measurement. Source and display: Input A, input A and B Range: 15 s/div to 2 days per division (automatic) Recorded timespan: Up to 16 days with a resolution of 1.5 hours Recording mode: Continuous with automatic vertical scaling and horizontal time compression Measurement speed: 2.5 measurements per second maximum Horizontal scale: Time from start General specifications Case Design: Rugged, shock proof with integrated protective holster Drip and dust proof: IP51 according to IEC529 Shock and vibration: Shock 30 g Vibration 3 g (sinusoidal) according to MIL-PRF-28800F Class 2 Display Bright LCD with CCFL backlight, 60 (35) cd/m2 with (without) power adapter Size: 72 x 72 mm (2.8 x 2.8 inch) Resolution: 240 x 240 pixels Contrast and brightness: User adjustable, temperature compensated Memory save and recall: 20 instrument screens with user set-ups and user text Real-time clock: Time and date stamp TrendPlot recording Power Line power: Country-specific line voltage adapter/battery charger included Battery power: Rechargeable BP120MH Battery operating time: Up to 5 hours using BP120MH Battery charging time: 5 hours Battery power saving functions:Auto power down with adjustable power down time. On-screen battery power indicator Mechanical data Size: 50 x 115 x 232 mm (2 x 4.5 x 9.1 in) Weight: 1.2 kg (2.64 lbs) Safety Compliance: EN61010.1 (2nd Edition) Pollution degree 2, UL3111-1, CAN/CSA-C22.2 No. 1010.1, ANSI/ISA S82.01 Input voltage ratings Maximum input voltage: 600 V CAT III (Maximum voltage between input and reference lead) Maximum input voltage using VPS40 Probe: 600 V CAT III, 1000 V CAT II (Maximum voltage between probe tip input and reference lead) Floating voltage: 600 V CAT III (Maximum voltage between earth ground and any terminal [signal input or reference lead]) Maximum voltage between reference leads: Instrument has common grounds connected via self recovering fault protection. For different ground potential measurements between inputs, use DP120 differential voltage probe Environmental Operating temperature: 0°C to +50°C Storage temperature: -20 °C to +60 °C Humidity: 10 ° to 30 °C, 95% RH non condensing; 30 °C to 40 °C, 75% RH non condensing; 40 °C to 50 °C, 45% RH non condensing Maximum operating altitude: 2,000 m (6,500 feet); 3,000 m (10,000 feet) voltages < 400 V Maximum storage altitude: 12 km (40,000 feet) Electro-Magnetic Compatibility: Emission EN50081-1 (EN55022 and EN60555-2) Immunity EN50082-2 (IEC1000-4-2, -3, -4, -5) Optically isolated PC/printer interface: To printer: Supports HP Laserjet,® Deskjet,® Epson FX/LQ and postscript printers via optional PAC91 To PC: Transfer instrument settings, screen images and data, compatible with FlukeView® software for Windows® via optional PM9080 Includes: Rechargeable battery pack (installed): BP120MH; Line voltage adapter/battery charger: PM8907; Voltage probes and accessories: STL120 Shielded Test lead set; VPS40 high impedance 10:1 probe; 40 MHz (black); HC120 hook clips; ground leads with mini alligator clips; BB120 BNC-to-shielded banana adapter; Multimeter test leads: TL75 hard point test lead set (1 black); i400 current clamp; User manual on CD, Getting started booklet.