Fluke-125 Scopemeter, 40 MHz, Industrial, Probe Included
- Techni-Tool Part #: 374TE1253
- Mfg Part #: FLUKE-125/003
- Sold per: EACH
- Available in stock: 0
- Estimated weight:
6.4 lb
Regular Price: $2,375.95
Your price: $2,375.95
Shipping:
- ScopeMeter 120 Series: Three-in-one simplicity
The compact ScopeMeter 120 Series is the rugged solution for industrial troubleshooting and installation applications. It's a truly integrated test tool, with oscilloscope, multimeter and "paperless" recorder in one affordable, easy-to-use instrument. Find fast answers to problems in machinery, instrumentation, control and power systems.
A dual input 40 MHz or 20 MHz digital oscilloscope Two 5,000 counts true-rms digital multimeters Cursor measurements A dual input TrendPlot recorder Connect-and-View trigger simplicity for hands-off operation Shielded test leads for oscilloscope, resistance, continuity and capacitance measurements Full bandwidth, VPS40 10:1 40 MHz probe included Up to seven hours battery operation 600 V CAT III safety certified Optically isolated RS-232 interface Rugged, compact case Bus Health test for industrial bus systems Power measurements and harmonics measurement.
For more info, please see the Technical Specifications tab.
- Specifications:
Oscilloscope mode
Vertical deflection
Bandwidth (risetime):
with VPS40 probes: 40 MHz
input A and B directly: 40 MHz
with STL120 Shielded Test Leads: 12.5 MHz
Instrument risetime (input directly): 8.75 ns
Number of inputs: 2
Input coupling: AC, DC with ground level indicator
Input sensitivity: 5 mV to 500 V/div (with the included VPS40 and STL120 shielded test leads measure up to 600 Vrms, CAT III)
Input voltage: 600 V CAT III.
Vertical resolution: 8 bit
Accuracy: ± (2 % of reading + 0.05 x range/div)
Input impedance: 1 M? ± 1 % // 225 pF with STL120 shielded test leads; 1 M? ± 1 % // 20 pF ± 3 pF with BB120; 5 M? ± 1 % // 15.5 pF with VPS40, 10:1 Voltage probe
Horizontal
Max. sample rate (both channels simultaneously): 2.5 GS/s for repetitive signals; 25 MS/s for single shot
Number of digitizers: 2
Maximum record length: 512 Min-Max points per input
Accuracy: ± (0.1 % of reading + 1 pixel)
Glitch detect: 40 ns
Display and acquisition
Display modes: Input A, input A and B, envelope, smooth
Acquisition modes: Normal (including glitch capture), single shot, roll
Trigger and delay
Source: Input A, input B, external via optional ITP120
Modes: Automatic Connect-and-View, Free Run, Edge, Single Shot, Video, Video Line
Connect-and-View: Advanced automatic triggering that recognizes signal patterns and automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable pictures of complex and dynamic signals like motor drive and control signals
Video triggering: NTSC, PAL, PAL+, SECAM. Includes line select
Time delay: Up to 10 divisions pre-trigger view
Measurements: Vdc, Vac, Vac+dc, Vpeak max, Vpeak min, Vpeak to peak, frequency (Hz), positive pulse width, negative pulse width, positive duty cycle, negative duty cycle, Amp ac, Amp dc, Amp ac+dc, Phase, Temperature °C, Temperature °F, dBV, dBm into 50 W and 600 W. (Amps, °C or °F with optional probes)
Cursor measurements
Sources: Input A, Input B
Modes: Single or dual vertical cursor, dual horizontal cursor, risetime or falltime
Measurements: Single vertical line: Average, min value, max value, time from start of recording in roll mode Dual vertical lines: V at markers, time between cursors, 1/T between cursors (in Hz) Dual horizontal lines: High, low or V - readout, risetime and falltime: transition time, 0 %-level, 100 %-level, with markers at 10% and 90%
Accuracy: As oscilloscope
Bus health tester: Bus health automatically analyzes the electrical signals on the network to give waveform data and measure individual parameters. Automatic comparison of the measurement results to the standards results in "good" or "false" indicators to be displayed per parameter.
Bus types and reference standards used:
AS-I (EN50295); CAN-bus (ISO-11898); Interbus S (EIA-485); ControlNet (61158 type 2); Modbus (EIA-232 and EIA-485); Foundation Fieldbus H1 (61158 type 1, 31.25 kb) and H2 (61158 type 1); Profibus DP (EIA-485) and PA (61158 type 1); Ethernet [10Base2 (coaxial) and 10BaseT (UTP)]; RS-232 (EIA-232); RS-485 (EIA-485); or user defined system
Measured parameters: Baud rate, risetime, falltime, high level, low level, distortion, amplitude and jitter, with comparison to system's standard values
Power measurements
Measure types: Watt, VA, VAR, Power Factor (PF)
Power configuration: Single phase or balanced 3-phase (delta-configuration) mains supply
Voltage measurement: Channel A, using STL120, voltage probe or direct input
Current measurement: Channel B, using i400s current clamp (included) or other compatible clamp
Current clamp sensitivity: 0.1/1/10/100/1000 mV/A, 10 mV/mA and 400 mV/A
Harmonics mode:Converts waveform information into a harmonics display (using FFT processing), which shows the relative amplitudes of the 1st up to the 33rd harmonic
Default setting: Harmonic contents of the power waveform
Harmonics frequency range: DC to 33rd harmonic (fundamental < 60 Hz); DC to 24th (fundamental < 400 Hz)
Analyzed waveform:Voltage waveform (Ch.A), current waveform (Ch.B) or power (Ch.A x Ch.B), automatically generated
Display: Bargraph showing 1st up to 33rd harmonic, amplitude displayed in % relative to fundamental Timebase setting: 5 ms/div.
Measurements: Relative amplitude of individual harmonic; THD in %r or %f
Dual input meter: The specified accuracy is valid over the temperature range 18°C to 28° C (64°F to 82°F). Add 10 % of specified accuracy for each °C below 18°C or above 28°C (64°F to 82°F)
Max. meter bandwidth: 40 MHz
Voltage measurements
Measurement selection: Vdc, Vac rms, Vac+dc rms, Vpeak max, Vpeak min, Vpk-pk
Ranges: 500 mV, 5 V, 50 V, 500 V, 1250 V
Full scale reading: 5,000 counts
Accuracy
Vdc: ± (0.5 % + 5 counts)
Vac rms:
1 Hz to 60 Hz: ± (1 % + 10 counts)
60 Hz to 1 kHz: ± (2.5 % + 15 counts)
20 kHz to 1 MHz ± (5 % + 20 counts)
Vac+dc true-rms:
DC to 60 Hz: ± (1 % + 10 counts)
60 Hz to 1 kHz: ± (2.5 % + 15 counts)
20 kHz to 1 MHz (5 % + 20 counts)
Vpeak:
Max peak or Min peak: 5 % of full scale
Peak-to-peak: 10 % of full scale
Ohms
Ranges: 500 W, 5 kW, 50 kW, 500 kW, 5 MW, 30 MW, 50.00 W
Max. resolution: 5,000 counts
Accuracy: ± (0.6 % of reading + 5 counts)
Capacitance
Ranges: 50 nF to 500 µF
Max. resolution: 5,000 counts
Accuracy: ± (2 % of reading + 10 counts)
Other meter functions
Frequency: Up to 70 MHz
Rotational speed (RPM): Revolutions per minute, based on 1, 2 or 4 or 8 pulses per 2 revolutions
Continuity: Beeper on < 30 ?
Diode test: Up to 2.8 V
Amps: Amp dc, Amp ac, Amp ac+dc using an optional current clamp or shunt. Scaling factors: 0.1 mV/Amp to100 V/Amp
Temperature (°C, °F): With optional accessories. Scale factors 1 mV/°C or 1 mV/°F
Number of inputs: 2
Input impedance: 1 M? ± 1 % // 10 pF ± 2 Pf
Advanced meter functions: Auto/manual ranging, TouchHold®, Relative measurements (zero reference), TrendPlot recording
Recorder mode
Trendplot recording
Dual input electronic paperless chart recorder. Plots and displays the actual, minimum, maximum and average of any measurement.
Source and display: Input A, input A and B
Range: 15 s/div to 2 days per division (automatic)
Recorded timespan: Up to 16 days with a resolution of 1.5 hours
Recording mode: Continuous with automatic vertical scaling and horizontal time compression
Measurement speed: 2.5 measurements per second maximum
Horizontal scale: Time from start
General specifications
Case
Design: Rugged, shock proof with integrated protective holster
Drip and dust proof: IP51 according to IEC529
Shock and vibration: Shock 30 g Vibration 3 g (sinusoidal) according to MIL-PRF-28800F Class 2
Display
Bright LCD with CCFL backlight, 60 (35) cd/m2 with (without) power adapter
Size: 72 x 72 mm (2.8 x 2.8 inch)
Resolution: 240 x 240 pixels
Contrast and brightness: User adjustable, temperature compensated
Memory save and recall: 20 instrument screens with user set-ups and user text
Real-time clock: Time and date stamp TrendPlot recording
Power
Line power: Country-specific line voltage adapter/battery charger included
Battery power: Rechargeable BP120MH
Battery operating time: Up to 5 hours using BP120MH
Battery charging time: 5 hours
Battery power saving functions:Auto power down with adjustable power down time. On-screen battery power indicator
Mechanical data
Size: 50 x 115 x 232 mm (2 x 4.5 x 9.1 in)
Weight: 1.2 kg (2.64 lbs)
Safety Compliance: EN61010.1 (2nd Edition) Pollution degree 2, UL3111-1, CAN/CSA-C22.2 No. 1010.1, ANSI/ISA S82.01
Input voltage ratings
Maximum input voltage: 600 V CAT III (Maximum voltage between input and reference lead)
Maximum input voltage using VPS40 Probe: 600 V CAT III, 1000 V CAT II (Maximum voltage between probe tip input and reference lead)
Floating voltage: 600 V CAT III (Maximum voltage between earth ground and any terminal [signal input or reference lead])
Maximum voltage between reference leads: Instrument has common grounds connected via self recovering fault protection. For different ground potential measurements between inputs, use DP120 differential voltage probe
Environmental
Operating temperature: 0°C to +50°C
Storage temperature: -20 °C to +60 °C
Humidity:
10 ° to 30 °C, 95% RH non condensing;
30 °C to 40 °C, 75% RH non condensing;
40 °C to 50 °C, 45% RH non condensing
Maximum operating altitude: 2,000 m (6,500 feet); 3,000 m (10,000 feet) voltages < 400 V Maximum storage altitude: 12 km (40,000 feet)
Electro-Magnetic Compatibility: Emission EN50081-1 (EN55022 and EN60555-2) Immunity EN50082-2 (IEC1000-4-2, -3, -4, -5)
Optically isolated PC/printer interface: To printer: Supports HP Laserjet,® Deskjet,® Epson FX/LQ and postscript printers via optional PAC91 To PC: Transfer instrument settings, screen images and data, compatible with FlukeView® software for Windows® via optional PM9080
Includes: Rechargeable battery pack (installed): BP120MH; Line voltage adapter/battery charger: PM8907; Voltage probes and accessories: STL120 Shielded Test lead set; VPS40 high impedance 10:1 probe; 40 MHz (black); HC120 hook clips; ground leads with mini alligator clips; BB120 BNC-to-shielded banana adapter; Multimeter test leads: TL75 hard point test lead set (1 black); i400 current clamp; User manual on CD, Getting started booklet.
|
|
|
|