B & K Precision
BK Precision Power Supply, 1672, Triple Output, DC

  • Techni-Tool Part #: 310TE1672
  • Mfg Part #: 1672
  • Sold per: EACH
  • Estimated weight: 18.58 lb
Enter Amount $
 

This item has been added to your favorites

You must be logged in to add an item to your favorites, click here to login.
New customer? Click here to register.

Please select a value for each option before adding to your Favorites.

Close

  • The Model 1672 is a Quad Display Triple Output DC Regulated Power Supply that provides one fixed output (5V/ 3A) and two variable outputs (0 - 32V/ 0 - 3A) ratings. The four displays allows the user to continuously monitor the voltage and current values of the two main outputs. The variable outputs can work independently, or in series tracking, or parallel mode.

    Features
    • Independent control of Voltage and Current for variable output
    • CV/CC operation
    • Separate 3 digit displays for voltage (Green) and current (Red) for both variable outputs
    • LED indication for CV (Green) and CC (Red) modes
    • Overload indication LED for Fixed output
    • Series tracking and parallel mode operation for Triple output unit
    • Output terminals are banana style (not binding posts), click on
    • Accessories for leads
  • Specifications:

    Output Voltage
    Master Output:
    0 to 32 VDC
    Slave Output: 0 to 32 VDC
    Fixed: 5 VDC (±0.85V)

    Output Current
    Master Output:
    0 to 3 A
    Slave Output: 0 to 3 A
    Fixed Output: 0 to 3 A

    Constant Voltage Operation
    Voltage Regulation
    Line (120 VAC ± 10%):
    <= 0.01% + 5 mV
    5V Fixed Output is Not Specified
    Load: <= 0.2% + 10 mV
    5V Fixed Output is Not Specified

    Ripple & Noise: <= 1mVrms

    Temperature Coefficient: <= 300 ppm °C

    Constant Current Operation:
    Adjustable Current Range:
    5% to 100% (Main)

    Current Regulation
    Line (120 VAC ± 10%):
    <= 0.01% + 5 mA
    Load: <= 0.2% + 8 mA

    Current Ripple: <= 1 mA rms

    Metering
    Display:
    4 digital LED
    Voltmeter Range00.0 to 99.9
    Voltmeter Accuracy: ±(0.1% reading + 3 digit)
    Ampmeter Range: 00.0 to 99.9
    Ampmeter Accuracy: ±(0.1% reading + 3 digit)

    Overload Protection<Current limiting, Reverse polarity, overvoltage, Short circuit

    Power Requirements: 115/230 VAC (±10%), 60 Hz

    Operating Temperature: 10° to 40°C<=90% R.H.

    Dimensions (H x W x D): 9" x 7" x 12.2" (230 x 2170 x 310 mm)
    Weight: 12.6 lbs. (5.7 kg)